Nortel Networks                       Updated: 2/4/2000

Optivity NMS OIT Package README for New Device/Agent:
BayStack 450 10/100/1000 Series Autosense Switch, agent software v2.0

===========================================================================

OIT PACKAGE SUMMARY:
====================

This document contains installation instructions, new feature, and known
restriction information for Optivity Integration Toolkit (OIT) files when 
used with the BayStack 450 Switch and version 2.0 software. These OIT 
installation instructions are not included in the Optivity and BayStack 
450 Switch documentation.  Manual installation of this OIT file will be
required for Optivity NMS v9.0.x releases.  For Optivity NMS 9.0 this OIT 
file requires the NMS 9.0.0.2 patch to be installed.

Note: To use Optivity to manage a standalone 450 or a stack of 450s, install
this OIT package.  To manage a mixed stack of 450s and 410s you must install
both the 450 and the 410 OIT packages.




DEVICES SUPPORTED:
====================

BayStack 450 10/100/1000 Series Autosense switches, running agent software v2.0
on the following BayStack devices with sysObjectID 1.3.6.1.4.1.45.3.35.1 
and 1.3.6.1.4.1.45.3.36.1

 BayStack 450-12T (Chameleon 100) with Chassis ID 654
 BayStack 450-24T (Chameleon 100) with Chassis ID 653
 BayStack 450-12T (Chameleon 200) with Chassis ID 674
 BayStack 450-24T (Chameleon 200) with Chassis ID 667
 BayStack 450-12F (Firefly)       with Chassis ID 681
 BayStack 410-24T (Chameleon 10)  with Chassis ID 655

Chassis ID is available in the s5ChasComTable

NOTE: **** This OIT package requires NMS 9.0.0.2 or later ****

If you previously installed the NMS-bs450-v20-A OIT package, you must install this
NMS-bs450-v20-B OIT package.



NOTES FOR INSTALLATION:
=======================

The default locations for an Optivity install are:
Unix ($OITHOME):			/usr/oit
Windows 95/98/NT (%OITHOME%):		<DRIVE_LETTER>:\Optivity\OIT

All installation commands are relative to the directory containing the
extracted (un-tarred or un-zipped) OIT package.  The following commands should
be executed in that directory.

Installing on UNIX
------------------
1. Install the NMS 9.0.0.2 patch (not required with NMS 9.0.1 or later).

2. On your workstation, log into Optivity NMS as root (su command).

3. Open a unix shell window and prepare your user environment with one of
   the following commands:
      source /opt/lnms/bin/opt_cshrc (for csh and tcsh)
      . /opt/lnms/bin/opt_kshrc (for sh or ksh)

4. In the /usr/oit directory, create the following subdirectory structures:
      mkdir ${OITHOME}/wpd/baystack/common/

5. Copy contents of the OIT package to various locations:
      cp *.gif ${LNMSHOME}/images/chassis
      cp *.mib ${OITHOME}/wpd/baystack/common
      cp *.mi1 ${OITHOME}/wpd/baystack/common
      cp NMS-bs450-v20-B.oit ${OITHOME}/wpd/baystack

6. At the command prompt, type (you must have superuser permissions):
      oitInstall -u $OITHOME/wpd/baystack/NMS-bs450-v20-B.oit
   where -u indicates to upgrade Optivity NMS. If you do not specify 
   the -u parameter, a syntax check only is performed on the OIT file. 


Installing on PC
----------------
1. Install the NMS 9.0.0.2 patch (not required with NMS 9.0.1 or later).

2. On your workstation, log in as administrator

3. Open a command prompt

4. In the \usr\oit directory, create the following subdirectory structures:
      mkdir %OITHOME%\wpd\baystack\common\

5. Copy contents of the OIT package to various locations:
      copy *.gif %LNMSHOME%\images\chassis
      copy *.mib %OITHOME%\wpd\baystack\common
      copy *.mi1 %OITHOME%\wpd\baystack\common
      copy NMS-bs450-v20-B.oit %OITHOME%\wpd\baystack

6. Run the oitInstall executable as follows:
      oitInstall -u %OITHOME%\wpd\baystack\NMS-bs450-v20-B.oit
   where -u indicates to upgrade Optivity NMS. If you do not specify 
   the -u parameter, a syntax check only is performed on the OIT file. 


Installation Results
--------------------
When you installed Optivity NMS, the installation program copied an 
oitinstalled.cnf file and an oitapplied.cnf file to the default location.
These were empty files. When you upgrade Optivity NMS with new device
support, these files are updated with an entry for the new device support.
The contents of the oitinstalled.cnf and oitapplied.cnf in the file should
be the same.  An entry in each of the *.cnf files is as follows (each
installed OIT package creates a line of format "<oit filename> <absolute
path for oit file location>"):

# This file contains all the OIT updates that are potential 
# update candidates.

<oit filename> <absolute path for oit file>

(UNIX EXAMPLE)

NMS-bs350-v20-B.oit /usr/oit/wpd/baystack
NMS-bs410-v20-B.oit /usr/oit/wpd/baystack
NMS-bs450-v20-B.oit /usr/oit/wpd/baystack




NEW FEATURES IN THIS RELEASE:
=============================

-- Autotopology.  With this OIT package, links between BayStack and other
   Nortel network devices can be automatically detected and depicted in 
   the InfoCenter Datalink Layer View and InfoCenter Physical Layer View 
   options (by using the Format > Graphical menu option).

-- Expanded View support
     o BayStack 450-12F and 410-24T supported
     o Many fixes to LED mapping

-- OmniView support
     o  Autotopology (s5 Ethernet Multi-Segment Topology MIB)
     o  Multi-Link Trunks Configuration and Statistics (Rapid City Enterprise
	MIB)
     o  Spanning Tree Groups and Ports (Rapid City Enterprise MIB)
     o  Detailed Port Information (Rapid City Enterprise MIB)

-- Fault Manager support
     o  Unit Up/Down Traps (s5CtrUnitUp and s5CtrUnitDown)
     o  Base Unit Failed Trap (s5CtrProblem)




OLD FEATURES REMOVED IN THIS RELEASE:
=====================================

None




BUGS FIXED IN THIS RELEASE:
===========================

Leds incorrectly depicted in Expanded View for many units and MDAs

CR # 110836-1


FILES ASSOCIATED WITH THIS OIT KIT:
===================================

README.txt
bbs41024.gif
bbs45012.gif
bbs45012f.gif
bbs45012t.gif
bbs45024.gif
bbs45024t.gif
bmda1lx.gif
hbsrj45rf.gif
NMS-bs450-v20-B.oit
rfc1213.mib
rfc1493.mib
rfc1643.mib
rfc1757.mib
rfc1902v.mi1
rfc1903v.mi1
rvlan000.mib
s5age140.mib
s5cha127.mib
s5emt104.mib
s5ifx100.mib
s5roo115.mib
s5tcs112.mib
synro167.mib




KNOWN LIMITATIONS:
==================

-- After installation of the NMS 9.0.0.2 patch and the 350/410/450 V2.0
   OIT packages and a subsequent rediscovery of any subnets which contain
   these devices, it may appear that some of the devices have "duplicates"
   within the InfoCenter subnet view. These "duplicates" are actually two
   different database object representations of the same device in the
   subnet. They appear to be duplicates because the label names are the
   same.

   This situation can be corrected in the following manner:

   	1. On Unix based systems, use a text editor to open the file:

        	$LNMSHOME/apps/topology/topology.cnf

        	On NT based systems the file is:

	        %LNMSHOME%\apps\topology\topology.cnf

   	2. Change the value for the "Age_Out_Period" parameter to 0 (the number
	   Zero).

        3. Save the file.

        4. Run the topology "rediscover" process for any subnets which exhibit
           the problem.

   This will clear most (if not all) situations of this type. If the effect
   is not seen immediately, it may be necessary to simply refresh the
   InfoCenter subnet view which you might have had open when you ran the
   rediscover process against the subnet. In most cases the view will
   refresh itself. When you are finished, it is advisable to return the
   Age_Out_Period value back to your normal setting.

-- When you use the Datalink and Physical views, you must use the graphical 
   format in order for the layout options to display accurately.

-- ExpandedView does not operate correctly if a stack does not contain a unit 1
	CR # 115717-1

-- ExpandedView shortcut menus (using the right mouse button to show port
   information) will display information for the relative port on unit 1
   regardless if which unit the port or MDA is selected from.
	CR # 117867-1

-- OmniView shows incorrect speed/duplex under Port Detail for GigaBit Ethernet
    MDA ports
	CR # 114040-1

-- OmniView RMON->History Table displays error message "Pane is not supported"
	CR # 113708-1

-- OPTIVITY Threshold Manager application is not supported
	CR # 118349-1

-- Slot numbers are incorrect on distributed MLT links on stack units 4 and 8
	CR # 118146-1

-- The OmniView pane, "Port Detail" displays all ports in a stack by ifIndex
   number.  To determine which slot number an ifIndex is referring to, use
   the following table.  You can calculate the port number by subtracting the
   beginning of a given unit's range from the ifIndex number in question:

	       ifIndex range	UNIT Number
	       1 - 32		1
	       33 - 64		2
	       65 - 96		3
	       97 - 128		4
	       129 - 160	5
	       161 - 192	6
	       193 - 224	7
	       225 - 256	8

-- Platform integration for Openview, NetView, and Solstice Domain Manager
   is not implemented with this version of the OIT package.


(c) 1998-2000 Nortel Networks Incorporated. All rights reserved.
===========================================================================